Prev: WDF EvtIoStop, are interrupts hooked when this callback is cal
Next: "Fake" Keyboard or Mouse driver
From: stvlai on 22 Feb 2007 13:20 Dear All I have been having Nightmare trying to get the Vista Logo Test running. Anyone knows anything, please help. Running a Vista Logo Test for LCD Monitor for the Master Config Job, it always seems to go into Debug Mode and Fail in the very first test call Create Dimension XSLT. Looking at the CHild Results under Create Dimension XSLT, I notice it fail in the Signal Data Source. It pass the other 3 test in this Child Result. When it fail the Signal Data SOurce test, it seems to abort all other test for the Master COnfig Job test. I have the Client User given the DTM Administrator, reinstall my DTM Controller. I don't know what I should do next. ALso, change at least 3 PC to get the Master COnfig Job but all fail at the Create DImension XSLT. Any good samaritan have any good ideas, please HELP! Thank you so much! SL
From: dmm on 13 Mar 2007 09:41
hi stvlai I have been having a similar (and very basic) problem. I create a dimension for the sample in "DTM Help, Generic Logo Submission exercise." When this dimension (for DisplayMonitorCRT) is applied, the Job Monitor shows that all tasks execute without error except "Deploy Dynamic System Update Manager - Copy Watchdog Manager." The full error chain is as follows: Failed to Start the Task "Deploy Dynamic System Update Manager - Copy Watchdog Manager" Zero files are copied when Trying to Copy From Path "\\ensure2003.ENSURETECH\DTMInstall\Gatherers\x86\WatchdogMgr.exe"....Failing the Task Resolution Zero files were copied. The CopyFile/CopyResult task has been marked failed. At least one file should be copied for the CopyFile/CopyResult task to pass. Failed to Copy File : "\\ensure2003.ENSURETECH\DTMInstall\Gatherers\x86\WatchdogMgr.exe" Dest : "C:\WTT\JobsWorkingDir\AssetCfg\" Resolution A Windows API Returned an unexpected error. Look at win32 error code in the inner error for more details. Root Cause Copying File From "\\ensure2003.ENSURETECH\DTMInstall\Gatherers\x86\WatchdogMgr.exe" to "C:\WTT\JobsWorkingDir\AssetCfg\WatchdogMgr.exe" Failed Error Code 32 (The process cannot access the file because it is being used by another process) Resolution No resolution provided. Did you make any progress in resolving your problem? Thanks dmm "stvlai" wrote: > Dear All > > I have been having Nightmare trying to get the Vista Logo Test > running. Anyone knows anything, please help. > > Running a Vista Logo Test for LCD Monitor for the Master Config Job, > it always seems to go into Debug Mode and Fail in the very first test > call Create Dimension XSLT. Looking at the CHild Results under Create > Dimension XSLT, I notice it fail in the Signal Data Source. It pass > the other 3 test in this Child Result. When it fail the Signal Data > SOurce test, it seems to abort all other test for the Master COnfig > Job test. > > I have the Client User given the DTM Administrator, reinstall my DTM > Controller. I don't know what I should do next. ALso, change at least > 3 PC to get the Master COnfig Job but all fail at the Create DImension > XSLT. > > Any good samaritan have any good ideas, please HELP! Thank you so > much! > > SL > > |