From: Michael A. Terrell on 7 Nov 2006 05:29 Charlie East wrote: > > Test D- -- Service to my country? Been there, Done that, and I've got my DD214 to prove it. Member of DAV #85. Michael A. Terrell Central Florida
From: Charlie East on 7 Nov 2006 17:21 Having trouble posting, The test worked, but still unable to post oroblem, Unit came in dead, H-out transistor shorted, removed tran and B+ is good, Installed another trans and set came on good, Played several hrs and turn off for the night. Next day set will not come on, H-out shorted again. Check caps with ESR meter, ring flyback ok, Replaced flyback and trans, set looked good, played for about half day, I turned it on and off several times, every thing good, Sent it home, Played two days and out again, Customer stated it was fine when she turned off at night, next day dead, Looks like the H-out is shorting during turn off or while the set is off, anyone got any Ideas Thanks Charlie "Michael A. Terrell" <mike.terrell(a)earthlink.net> wrote in message news:45505FD8.FF02B9C8(a)earthlink.net... > Charlie East wrote: > > > > Test > > > D- > > > -- > Service to my country? Been there, Done that, and I've got my DD214 to > prove it. > Member of DAV #85. > > Michael A. Terrell > Central Florida
|