From: Emmanuel Chantry on 14 Feb 2010 05:00 Le 14/02/2010 07:26, Alex Samad a �crit : > On Sat, Feb 13, 2010 at 08:42:42PM -0600, Stan Hoeppner wrote: > >> Emmanuel Chantry put forth on 2/13/2010 6:39 AM: >> >> >>> I've already tried this one. That works on virtual machine in amd64 but >>> not on the HP Server. It's the first thing I've done ;) >>> > smart arrays don't turn up as /dev/sda from memory /dev/cciss/c0d0 - > controller zero and disk zero > > as for the other problem, lvm writes information onto the hard drives, > which is why you are seeing the error message, I believe there is a way > to tell the partition manager to clear all partitions on the disk to be > installed onto. > > I would also stick to lvm on smartarrays, much easier to managing moving > lv's etc > > > >> Have you tried contacting HP support? IIRC, they support Debian. >> >> I'm not surprised that is a difference beetween VMs and real hardware. HP servers runs with CCISS driver not with standard sda I know that. I've tried to join HP support. First time, they said they don't support Debian lol. I have to send us their website URL to prove them they're supporting Debian... I'm waiting for an answer from the support if they know that problem. It seems that in amd64 and HP servers, install steps are not in the same order. In fact The cciss is loaded just before partman starts (installing scsci-modules and scsi-extra-modules) not at kernel boot. In preseed file, the line: d-i partman-lvm/device_remove_lvm boolean true tells that old LVM configuration have to be erased without prompting. But it doesn't work on my HP server. Emmanuel -- To UNSUBSCRIBE, email to debian-user-REQUEST(a)lists.debian.org with a subject of "unsubscribe". Trouble? Contact listmaster(a)lists.debian.org Archive: http://lists.debian.org/4B77C8D9.90905(a)gmail.com
From: Alex Samad on 14 Feb 2010 21:50
On Sun, Feb 14, 2010 at 10:56:41AM +0100, Emmanuel Chantry wrote: > Le 14/02/2010 07:26, Alex Samad a écrit : > >On Sat, Feb 13, 2010 at 08:42:42PM -0600, Stan Hoeppner wrote: > >>Emmanuel Chantry put forth on 2/13/2010 6:39 AM: [snip] > >> > I'm not surprised that is a difference beetween VMs and real > hardware. HP servers runs with CCISS driver not with standard sda I > know that. > I've tried to join HP support. First time, they said they don't > support Debian lol. I have to send us their website URL to prove > them they're supporting Debian... > I'm waiting for an answer from the support if they know that problem. > > It seems that in amd64 and HP servers, install steps are not in the > same order. In fact The cciss is loaded just before partman starts > (installing scsci-modules and scsi-extra-modules) not at kernel > boot. > > In preseed file, the line: d-i partman-lvm/device_remove_lvm > boolean true tells that old LVM configuration have to be erased > without prompting. But it doesn't work on my HP server. Hi I have done quite a few installs on DL360, Dl785's, but all manual not with pre seed. So I can tell you it works okay - the problem is with the installer. > > Emmanuel > > -- "It'll be hard to articulate." - George W. Bush 01/01/2001 anticipating how he'll feel upon assuming the presidency |