From: Jack Hamilton on 14 Jan 2010 11:54 "&EndDate"d will work in a call to %SYSFUNC: ===== 1 %let EndDate = 01Feb2010; 2 %let NewDate = %sysfunc(intnx(month, "&EndDate."d, -1), date9.); 3 %put &NewDate.; 01JAN2010 ===== The documentation (for 9.1, <http://support.sas.com/onlinedoc/913/getDoc/en/mcrolref.hlp/z3514sysfunc.htm>) says: Because %SYSFUNC is a macro function, you do not need to enclose character values in quotation marks as you do in DATA step functions. For example, the arguments to the OPEN function are enclosed in quotation marks when the function is used alone, but do not require quotation marks when used within %SYSFUNC. I think that the documentation as written is incorrect. To me, "not required" is not the same as "not allowed". In general, SAS does not take the "everything that is not compulsory is forbidden" approach, but in this case it appears that they do. Note that it talks about character values, not numeric values. The second argument to INTNX is numeric, not character, so it is not obvious that quotes are forbidden there. And indeed, quotes, in the context of a date constant, are allowed in this case. Interestingly, a quoted hex character constant is not allowed for the first, character, argument: ===== 4 %put %sysfunc(putc(month, $hex10.)); 6D6F6E7468 5 %let EndDate = 01Feb2010; 6 %let NewDate = %sysfunc(intnx('6D6F6E7468'x, "&EndDate."d, -1), date9.); WARNING: An argument to the function INTNX referenced by the %SYSFUNC or %QSYSFUNC macro function is out of range. NOTE: Mathematical operations could not be performed during %SYSFUNC function execution. The result of the operations have been set to a missing value. 7 %put &NewDate.; .. ===== That syntax does work in the data step: ===== 20 data _null_; 21 newdate = intnx('6D6F6E7468'x, "&EndDate."d, -1); 22 put newdate=date9.; 23 run; newdate=01JAN2010 ===== You can use a hex constant for the date value: ===== 30 %put %sysfunc(putn("01feb2010"d, hex8.)); 00004776 31 32 %let NewDate = %sysfunc(intnx(month, 00004776x, -1), date9.); 33 %put &NewDate.; 01JAN2010 ===== You can use scientific notation: ===== 38 %put %sysfunc(putn("01feb2010"d, e12.)); 1.82940E+04 39 40 %let NewDate = %sysfunc(intnx(month, 1.82940E+04, -1), date9.); 41 %put &NewDate.; 01JAN2010 ===== So what conclusion can we draw about what kinds of arguments are allowed? It appears that for numeric parameters you can use a number (in decimal, hexadecimal, or scientific notation) or a date constant (and presumably time and datetime constants as well). For character parameters you can use only unquoted strings. You can't use constants in hexadecimal notation. On Wed, 13 Jan 2010 13:29 -0600, "Joe Matise" <snoopy369(a)GMAIL.COM> wrote: > First off, I believe SYSFUNC arguments are intended to be unquoted (no ' > " > ). 'month' should be month (no quotes). > > Secondly, "&EndDate"d won't work in the SYSFUNC, as far as I can tell. > You'll need to either pass it as a date value, or inside the sysfunc > input > it into a date value. > > Finally, you are recursively referenceing EndDate in the %let statement - > probably not good idea. It doesn't do any harm, but it makes it > difficult > to see the errors. > > This works, for example: > > %macro test( StartDate, EndDate); > %let EndDate=%sysfunc(intnx('month',&EndDate,1)); > %let StartDate=01&StartDate.; > %let where="&StartDate."d<=model<="&EndDate."d; > %mend(test); > > %test( jan09, 17198); > > -Joe > > > > On Wed, Jan 13, 2010 at 12:53 PM, Masoud Pajoh <mpajoh(a)odot.org> wrote: > > > All: > > The following is a fragment of a much larger macro. > > > > %macro test( StartDate, EndDate); > > %let EndDate=%sysfunc(intnx('month',"&EndDate."d,1)); > > %let StartDate=01&StartDate.; > > %let where="&StartDate."d<=model<="&EndDate."d; > > %mend(test); > > > > %test( jan09, dec09); > > > > WHERE should resolve to "01jan09"d<=model<="01jan10"d > > But, I get: > > > > WARNING: An argument to the function INTNX referenced by the %SYSFUNC or > > %QSYSFUNC macro function is out of range. > > > > What is wrong? > > > > Thanks, > > > > Masoud > > -- Brevis esse laboro, obscurus fio. Jack Hamilton Sacramento, California jfh(a)alumni.stanford.org
From: Masoud Pajoh on 14 Jan 2010 12:57 Is this a related question? In the following: %let EndDate = 01Mar2010; %let StartDate = 01Dec2009; %let s="&Start."d; %let e="&End."d; %let test=%sysfunc(intck(d,&e.,&s.)); %put &test.; Here is the log: 1 %let EndDate = 01Mar2010; 2 %let StartDate = 01Dec2009; 3 %let s="&StartDate."d; SYMBOLGEN: Macro variable STARTDATE resolves to 01Dec2009 4 %let e="&EndDate."d; SYMBOLGEN: Macro variable ENDDATE resolves to 01Mar2010 5 %let test=%sysfunc(intck(d,&e.,&s.)); SYMBOLGEN: Macro variable E resolves to "01Mar2010"d SYMBOLGEN: Macro variable S resolves to "01Dec2009"d WARNING: An argument to the function INTCK referenced by the %SYSFUNC or %QSYSFUNC macro function is out of range. NOTE: Mathematical operations could not be performed during %SYSFUNC function execution. The result of the operations have been set to a missing value. 6 %put &test.; SYMBOLGEN: Macro variable TEST resolves to . Thanks, Masoud Jack Hamilton <jfh(a)stanfordalumni.org> Sent by: "SAS(r) Discussion" <SAS-L(a)LISTSERV.UGA.EDU> 01/14/2010 10:54 AM Please respond to jfh(a)stanfordalumni.org To SAS-L(a)LISTSERV.UGA.EDU cc Subject Re: Macro question "&EndDate"d will work in a call to %SYSFUNC: ===== 1 %let EndDate = 01Feb2010; 2 %let NewDate = %sysfunc(intnx(month, "&EndDate."d, -1), date9.); 3 %put &NewDate.; 01JAN2010 ===== The documentation (for 9.1, < http://support.sas.com/onlinedoc/913/getDoc/en/mcrolref.hlp/z3514sysfunc.htm >) says: Because %SYSFUNC is a macro function, you do not need to enclose character values in quotation marks as you do in DATA step functions. For example, the arguments to the OPEN function are enclosed in quotation marks when the function is used alone, but do not require quotation marks when used within %SYSFUNC. I think that the documentation as written is incorrect. To me, "not required" is not the same as "not allowed". In general, SAS does not take the "everything that is not compulsory is forbidden" approach, but in this case it appears that they do. Note that it talks about character values, not numeric values. The second argument to INTNX is numeric, not character, so it is not obvious that quotes are forbidden there. And indeed, quotes, in the context of a date constant, are allowed in this case. Interestingly, a quoted hex character constant is not allowed for the first, character, argument: ===== 4 %put %sysfunc(putc(month, $hex10.)); 6D6F6E7468 5 %let EndDate = 01Feb2010; 6 %let NewDate = %sysfunc(intnx('6D6F6E7468'x, "&EndDate."d, -1), date9.); WARNING: An argument to the function INTNX referenced by the %SYSFUNC or %QSYSFUNC macro function is out of range. NOTE: Mathematical operations could not be performed during %SYSFUNC function execution. The result of the operations have been set to a missing value. 7 %put &NewDate.; .. ===== That syntax does work in the data step: ===== 20 data _null_; 21 newdate = intnx('6D6F6E7468'x, "&EndDate."d, -1); 22 put newdate=date9.; 23 run; newdate=01JAN2010 ===== You can use a hex constant for the date value: ===== 30 %put %sysfunc(putn("01feb2010"d, hex8.)); 00004776 31 32 %let NewDate = %sysfunc(intnx(month, 00004776x, -1), date9.); 33 %put &NewDate.; 01JAN2010 ===== You can use scientific notation: ===== 38 %put %sysfunc(putn("01feb2010"d, e12.)); 1.82940E+04 39 40 %let NewDate = %sysfunc(intnx(month, 1.82940E+04, -1), date9.); 41 %put &NewDate.; 01JAN2010 ===== So what conclusion can we draw about what kinds of arguments are allowed? It appears that for numeric parameters you can use a number (in decimal, hexadecimal, or scientific notation) or a date constant (and presumably time and datetime constants as well). For character parameters you can use only unquoted strings. You can't use constants in hexadecimal notation. On Wed, 13 Jan 2010 13:29 -0600, "Joe Matise" <snoopy369(a)GMAIL.COM> wrote: > First off, I believe SYSFUNC arguments are intended to be unquoted (no ' > " > ). 'month' should be month (no quotes). > > Secondly, "&EndDate"d won't work in the SYSFUNC, as far as I can tell. > You'll need to either pass it as a date value, or inside the sysfunc > input > it into a date value. > > Finally, you are recursively referenceing EndDate in the %let statement - > probably not good idea. It doesn't do any harm, but it makes it > difficult > to see the errors. > > This works, for example: > > %macro test( StartDate, EndDate); > %let EndDate=%sysfunc(intnx('month',&EndDate,1)); > %let StartDate=01&StartDate.; > %let where="&StartDate."d<=model<="&EndDate."d; > %mend(test); > > %test( jan09, 17198); > > -Joe > > > > On Wed, Jan 13, 2010 at 12:53 PM, Masoud Pajoh <mpajoh(a)odot.org> wrote: > > > All: > > The following is a fragment of a much larger macro. > > > > %macro test( StartDate, EndDate); > > %let EndDate=%sysfunc(intnx('month',"&EndDate."d,1)); > > %let StartDate=01&StartDate.; > > %let where="&StartDate."d<=model<="&EndDate."d; > > %mend(test); > > > > %test( jan09, dec09); > > > > WHERE should resolve to "01jan09"d<=model<="01jan10"d > > But, I get: > > > > WARNING: An argument to the function INTNX referenced by the %SYSFUNC or > > %QSYSFUNC macro function is out of range. > > > > What is wrong? > > > > Thanks, > > > > Masoud > > -- Brevis esse laboro, obscurus fio. Jack Hamilton Sacramento, California jfh(a)alumni.stanford.org
From: "Data _null_;" on 14 Jan 2010 13:05 Argument 1 to INTNX you have d that is invalid perhaps you mean DAY. On 1/14/10, Masoud Pajoh <mpajoh(a)odot.org> wrote: > Is this a related question? > > In the following: > > %let EndDate = 01Mar2010; > %let StartDate = 01Dec2009; > %let s="&Start."d; > %let e="&End."d; > %let test=%sysfunc(intck(d,&e.,&s.)); > %put &test.; > > Here is the log: > > 1 %let EndDate = 01Mar2010; > 2 %let StartDate = 01Dec2009; > 3 %let s="&StartDate."d; > SYMBOLGEN: Macro variable STARTDATE resolves to 01Dec2009 > 4 %let e="&EndDate."d; > SYMBOLGEN: Macro variable ENDDATE resolves to 01Mar2010 > 5 %let test=%sysfunc(intck(d,&e.,&s.)); > SYMBOLGEN: Macro variable E resolves to "01Mar2010"d > SYMBOLGEN: Macro variable S resolves to "01Dec2009"d > WARNING: An argument to the function INTCK referenced by the %SYSFUNC or > %QSYSFUNC macro function is out of range. > NOTE: Mathematical operations could not be performed during %SYSFUNC > function execution. The result of the operations have been set to a > missing value. > 6 %put &test.; > SYMBOLGEN: Macro variable TEST resolves to . > > Thanks, > > Masoud > > > > > > Jack Hamilton <jfh(a)stanfordalumni.org> > Sent by: "SAS(r) Discussion" <SAS-L(a)LISTSERV.UGA.EDU> > 01/14/2010 10:54 AM > Please respond to > jfh(a)stanfordalumni.org > > > To > SAS-L(a)LISTSERV.UGA.EDU > cc > > Subject > Re: Macro question > > > > > > > "&EndDate"d will work in a call to %SYSFUNC: > > ===== > 1 %let EndDate = 01Feb2010; > 2 %let NewDate = %sysfunc(intnx(month, "&EndDate."d, -1), date9.); > 3 %put &NewDate.; > 01JAN2010 > ===== > > The documentation (for 9.1, > < > http://support.sas.com/onlinedoc/913/getDoc/en/mcrolref.hlp/z3514sysfunc.htm > >) > says: > > Because %SYSFUNC is a macro function, you do not need to enclose > character > values in quotation marks as you do in DATA step functions. For > example, the > arguments to the OPEN function are enclosed in quotation marks when > the > function is used alone, but do not require quotation marks when used > within > %SYSFUNC. > > I think that the documentation as written is incorrect. To me, "not > required" is not the same as "not allowed". In general, SAS does not > take the "everything that is not compulsory is forbidden" approach, but > in this case it appears that they do. > > Note that it talks about character values, not numeric values. The > second argument to INTNX is numeric, not character, so it is not obvious > that quotes are forbidden there. And indeed, quotes, in the context of > a date constant, are allowed in this case. > > Interestingly, a quoted hex character constant is not allowed for the > first, character, argument: > > ===== > 4 %put %sysfunc(putc(month, $hex10.)); > 6D6F6E7468 > 5 %let EndDate = 01Feb2010; > 6 %let NewDate = %sysfunc(intnx('6D6F6E7468'x, "&EndDate."d, -1), > date9.); > WARNING: An argument to the function INTNX referenced by the %SYSFUNC or > %QSYSFUNC macro > function is out of range. > NOTE: Mathematical operations could not be performed during %SYSFUNC > function execution. The > result of the operations have been set to a missing value. > 7 %put &NewDate.; > . > ===== > > That syntax does work in the data step: > > ===== > 20 data _null_; > 21 newdate = intnx('6D6F6E7468'x, "&EndDate."d, -1); > 22 put newdate=date9.; > 23 run; > > newdate=01JAN2010 > ===== > > You can use a hex constant for the date value: > > ===== > 30 %put %sysfunc(putn("01feb2010"d, hex8.)); > 00004776 > 31 > 32 %let NewDate = %sysfunc(intnx(month, 00004776x, -1), date9.); > 33 %put &NewDate.; > 01JAN2010 > ===== > > You can use scientific notation: > > ===== > 38 %put %sysfunc(putn("01feb2010"d, e12.)); > 1.82940E+04 > 39 > 40 %let NewDate = %sysfunc(intnx(month, 1.82940E+04, -1), date9.); > 41 %put &NewDate.; > 01JAN2010 > ===== > > So what conclusion can we draw about what kinds of arguments are > allowed? > > It appears that for numeric parameters you can use a number (in decimal, > hexadecimal, or scientific notation) or a date constant (and presumably > time and datetime constants as well). > > For character parameters you can use only unquoted strings. You can't > use constants in hexadecimal notation. > > > > On Wed, 13 Jan 2010 13:29 -0600, "Joe Matise" <snoopy369(a)GMAIL.COM> > wrote: > > First off, I believe SYSFUNC arguments are intended to be unquoted (no ' > > " > > ). 'month' should be month (no quotes). > > > > Secondly, "&EndDate"d won't work in the SYSFUNC, as far as I can tell. > > You'll need to either pass it as a date value, or inside the sysfunc > > input > > it into a date value. > > > > Finally, you are recursively referenceing EndDate in the %let statement > - > > probably not good idea. It doesn't do any harm, but it makes it > > difficult > > to see the errors. > > > > This works, for example: > > > > %macro test( StartDate, EndDate); > > %let EndDate=%sysfunc(intnx('month',&EndDate,1)); > > %let StartDate=01&StartDate.; > > %let where="&StartDate."d<=model<="&EndDate."d; > > %mend(test); > > > > %test( jan09, 17198); > > > > -Joe > > > > > > > > On Wed, Jan 13, 2010 at 12:53 PM, Masoud Pajoh <mpajoh(a)odot.org> wrote: > > > > > All: > > > The following is a fragment of a much larger macro. > > > > > > %macro test( StartDate, EndDate); > > > %let EndDate=%sysfunc(intnx('month',"&EndDate."d,1)); > > > %let StartDate=01&StartDate.; > > > %let where="&StartDate."d<=model<="&EndDate."d; > > > %mend(test); > > > > > > %test( jan09, dec09); > > > > > > WHERE should resolve to "01jan09"d<=model<="01jan10"d > > > But, I get: > > > > > > WARNING: An argument to the function INTNX referenced by the %SYSFUNC > or > > > %QSYSFUNC macro function is out of range. > > > > > > What is wrong? > > > > > > Thanks, > > > > > > Masoud > > > > > > -- > Brevis esse laboro, obscurus fio. > > Jack Hamilton > Sacramento, California > jfh(a)alumni.stanford.org >
From: Jack Hamilton on 14 Jan 2010 13:17 d is not valid as a first argument to INTNX. You have to spell out day. In general, I think it's a bad idea to abbreviate SAS keywords. It doesn't always work. On Thu, 14 Jan 2010 11:57 -0600, mpajoh(a)ODOT.ORG wrote: Is this a related question? In the following: %let EndDate = 01Mar2010; %let StartDate = 01Dec2009; %let s="&Start."d; %let e="&End."d; %let test=%sysfunc(intck(d,&e.,&s.)); %put &test.; Here is the log: 1 %let EndDate = 01Mar2010; 2 %let StartDate = 01Dec2009; 3 %let s="&StartDate."d; SYMBOLGEN: Macro variable STARTDATE resolves to 01Dec2009 4 %let e="&EndDate."d; SYMBOLGEN: Macro variable ENDDATE resolves to 01Mar2010 5 %let test=%sysfunc(intck(d,&e.,&s.)); SYMBOLGEN: Macro variable E resolves to "01Mar2010"d SYMBOLGEN: Macro variable S resolves to "01Dec2009"d WARNING: An argument to the function INTCK referenced by the %SYSFUNC or %QSYSFUNC macro function is out of range. NOTE: Mathematical operations could not be performed during %SYSFUNC function execution. The result of the operations have been set to a missing value. 6 %put &test.; SYMBOLGEN: Macro variable TEST resolves to . Thanks, Masoud Jack Hamilton <jfh(a)stanfordalumni.org> Sent by: "SAS(r) Discussion" <SAS-L(a)LISTSERV.UGA.EDU> 01/14/2010 10:54 AM Please respond to jfh(a)stanfordalumni.org To SAS-L(a)LISTSERV.UGA.EDU cc Subject Re: Macro question "&EndDate"d will work in a call to %SYSFUNC: ===== 1 %let EndDate = 01Feb2010; 2 %let NewDate = %sysfunc(intnx(month, "&EndDate."d, -1), date9.); 3 %put &NewDate.; 01JAN2010 ===== The documentation (for 9.1, <[1]http://support.sas.com/onlinedoc/913/getDoc/en/mcrolref.hlp/z 3514sysfunc.htm>) says: Because %SYSFUNC is a macro function, you do not need to enclose character values in quotation marks as you do in DATA step functions. For example, the arguments to the OPEN function are enclosed in quotation marks when the function is used alone, but do not require quotation marks when used within %SYSFUNC. I think that the documentation as written is incorrect. To me, "not required" is not the same as "not allowed". In general, SAS does not take the "everything that is not compulsory is forbidden" approach, but in this case it appears that they do. Note that it talks about character values, not numeric values. The second argument to INTNX is numeric, not character, so it is not obvious that quotes are forbidden there. And indeed, quotes, in the context of a date constant, are allowed in this case. Interestingly, a quoted hex character constant is not allowed for the first, character, argument: ===== 4 %put %sysfunc(putc(month, $hex10.)); 6D6F6E7468 5 %let EndDate = 01Feb2010; 6 %let NewDate = %sysfunc(intnx('6D6F6E7468'x, "&EndDate."d, -1), date9.); WARNING: An argument to the function INTNX referenced by the %SYSFUNC or %QSYSFUNC macro function is out of range. NOTE: Mathematical operations could not be performed during %SYSFUNC function execution. The result of the operations have been set to a missing value. 7 %put &NewDate.; .. ===== That syntax does work in the data step: ===== 20 data _null_; 21 newdate = intnx('6D6F6E7468'x, "&EndDate."d, -1); 22 put newdate=date9.; 23 run; newdate=01JAN2010 ===== You can use a hex constant for the date value: ===== 30 %put %sysfunc(putn("01feb2010"d, hex8.)); 00004776 31 32 %let NewDate = %sysfunc(intnx(month, 00004776x, -1), date9.); 33 %put &NewDate.; 01JAN2010 ===== You can use scientific notation: ===== 38 %put %sysfunc(putn("01feb2010"d, e12.)); 1.82940E+04 39 40 %let NewDate = %sysfunc(intnx(month, 1.82940E+04, -1), date9.); 41 %put &NewDate.; 01JAN2010 ===== So what conclusion can we draw about what kinds of arguments are allowed? It appears that for numeric parameters you can use a number (in decimal, hexadecimal, or scientific notation) or a date constant (and presumably time and datetime constants as well). For character parameters you can use only unquoted strings. You can't use constants in hexadecimal notation. On Wed, 13 Jan 2010 13:29 -0600, "Joe Matise" <snoopy369(a)GMAIL.COM> wrote: > First off, I believe SYSFUNC arguments are intended to be unquoted (no ' > " > ). 'month' should be month (no quotes). > > Secondly, "&EndDate"d won't work in the SYSFUNC, as far as I can tell. > You'll need to either pass it as a date value, or inside the sysfunc > input > it into a date value. > > Finally, you are recursively referenceing EndDate in the %let statement - > probably not good idea. It doesn't do any harm, but it makes it > difficult > to see the errors. > > This works, for example: > > %macro test( StartDate, EndDate); > %let EndDate=%sysfunc(intnx('month',&EndDate,1)); > %let StartDate=01&StartDate.; > %let where="&StartDate."d<=model<="&EndDate."d; > %mend(test); > > %test( jan09, 17198); > > -Joe > > > > On Wed, Jan 13, 2010 at 12:53 PM, Masoud Pajoh <mpajoh(a)odot.org> wrote: > > > All: > > The following is a fragment of a much larger macro. > > > > %macro test( StartDate, EndDate); > > %let EndDate=%sysfunc(intnx('month',"&EndDate."d,1)); > > %let StartDate=01&StartDate.; > > %let where="&StartDate."d<=model<="&EndDate."d; > > %mend(test); > > > > %test( jan09, dec09); > > > > WHERE should resolve to "01jan09"d<=model<="01jan10"d > > But, I get: > > > > WARNING: An argument to the function INTNX referenced by the %SYSFUNC or > > %QSYSFUNC macro function is out of range. > > > > What is wrong? > > > > Thanks, > > > > Masoud > > -- Brevis esse laboro, obscurus fio. Jack Hamilton Sacramento, California jfh(a)alumni.stanford.org References 1. http://support.sas.com/onlinedoc/913/getDoc/en/mcrolref.hlp/z3514sysfunc.htm -- Brevis esse laboro, obscurus fio. Jack Hamilton Sacramento, California jfh(a)alumni.stanford.org
From: Gerhard Hellriegel on 14 Jan 2010 14:25 if you deal with dates in macro, I don't find it to be a good idea to make it to "01Mar2010"d. That is a string for macros, not a date. It is only a date in certain environments. I find it better, if you need a date to make it a date in &s and &e, like: %let EndDate = 01Mar2010; %let StartDate = 01Dec2009; %let s=%sysfunc(inputn(&startdate,date9.)); %let e=%sysfunc(inputn(&enddate,date9.)); %let test=%eval(&e.-&s.); %put &test.; It's also not a good idea to write it in &StartDate and use &Start... and, data _null_ meant INTCK instead of INTNX, but that is not necessary if you are dealing with DAY intervals. It is simply the difference in that case. Gerhard On Thu, 14 Jan 2010 12:05:31 -0600, Data _null_; <iebupdte(a)GMAIL.COM> wrote: >Argument 1 to INTNX you have d that is invalid perhaps you mean DAY. > >On 1/14/10, Masoud Pajoh <mpajoh(a)odot.org> wrote: >> Is this a related question? >> >> In the following: >> >> %let EndDate = 01Mar2010; >> %let StartDate = 01Dec2009; >> %let s="&Start."d; >> %let e="&End."d; >> %let test=%sysfunc(intck(d,&e.,&s.)); >> %put &test.; >> >> Here is the log: >> >> 1 %let EndDate = 01Mar2010; >> 2 %let StartDate = 01Dec2009; >> 3 %let s="&StartDate."d; >> SYMBOLGEN: Macro variable STARTDATE resolves to 01Dec2009 >> 4 %let e="&EndDate."d; >> SYMBOLGEN: Macro variable ENDDATE resolves to 01Mar2010 >> 5 %let test=%sysfunc(intck(d,&e.,&s.)); >> SYMBOLGEN: Macro variable E resolves to "01Mar2010"d >> SYMBOLGEN: Macro variable S resolves to "01Dec2009"d >> WARNING: An argument to the function INTCK referenced by the %SYSFUNC or >> %QSYSFUNC macro function is out of range. >> NOTE: Mathematical operations could not be performed during %SYSFUNC >> function execution. The result of the operations have been set to a >> missing value. >> 6 %put &test.; >> SYMBOLGEN: Macro variable TEST resolves to . >> >> Thanks, >> >> Masoud >> >> >> >> >> >> Jack Hamilton <jfh(a)stanfordalumni.org> >> Sent by: "SAS(r) Discussion" <SAS-L(a)LISTSERV.UGA.EDU> >> 01/14/2010 10:54 AM >> Please respond to >> jfh(a)stanfordalumni.org >> >> >> To >> SAS-L(a)LISTSERV.UGA.EDU >> cc >> >> Subject >> Re: Macro question >> >> >> >> >> >> >> "&EndDate"d will work in a call to %SYSFUNC: >> >> ===== >> 1 %let EndDate = 01Feb2010; >> 2 %let NewDate = %sysfunc(intnx(month, "&EndDate."d, -1), date9.); >> 3 %put &NewDate.; >> 01JAN2010 >> ===== >> >> The documentation (for 9.1, >> < >> http://support.sas.com/onlinedoc/913/getDoc/en/mcrolref.hlp/z3514sysfunc.ht m >> >) >> says: >> >> Because %SYSFUNC is a macro function, you do not need to enclose >> character >> values in quotation marks as you do in DATA step functions. For >> example, the >> arguments to the OPEN function are enclosed in quotation marks when >> the >> function is used alone, but do not require quotation marks when used >> within >> %SYSFUNC. >> >> I think that the documentation as written is incorrect. To me, "not >> required" is not the same as "not allowed". In general, SAS does not >> take the "everything that is not compulsory is forbidden" approach, but >> in this case it appears that they do. >> >> Note that it talks about character values, not numeric values. The >> second argument to INTNX is numeric, not character, so it is not obvious >> that quotes are forbidden there. And indeed, quotes, in the context of >> a date constant, are allowed in this case. >> >> Interestingly, a quoted hex character constant is not allowed for the >> first, character, argument: >> >> ===== >> 4 %put %sysfunc(putc(month, $hex10.)); >> 6D6F6E7468 >> 5 %let EndDate = 01Feb2010; >> 6 %let NewDate = %sysfunc(intnx('6D6F6E7468'x, "&EndDate."d, -1), >> date9.); >> WARNING: An argument to the function INTNX referenced by the %SYSFUNC or >> %QSYSFUNC macro >> function is out of range. >> NOTE: Mathematical operations could not be performed during %SYSFUNC >> function execution. The >> result of the operations have been set to a missing value. >> 7 %put &NewDate.; >> . >> ===== >> >> That syntax does work in the data step: >> >> ===== >> 20 data _null_; >> 21 newdate = intnx('6D6F6E7468'x, "&EndDate."d, -1); >> 22 put newdate=date9.; >> 23 run; >> >> newdate=01JAN2010 >> ===== >> >> You can use a hex constant for the date value: >> >> ===== >> 30 %put %sysfunc(putn("01feb2010"d, hex8.)); >> 00004776 >> 31 >> 32 %let NewDate = %sysfunc(intnx(month, 00004776x, -1), date9.); >> 33 %put &NewDate.; >> 01JAN2010 >> ===== >> >> You can use scientific notation: >> >> ===== >> 38 %put %sysfunc(putn("01feb2010"d, e12.)); >> 1.82940E+04 >> 39 >> 40 %let NewDate = %sysfunc(intnx(month, 1.82940E+04, -1), date9.); >> 41 %put &NewDate.; >> 01JAN2010 >> ===== >> >> So what conclusion can we draw about what kinds of arguments are >> allowed? >> >> It appears that for numeric parameters you can use a number (in decimal, >> hexadecimal, or scientific notation) or a date constant (and presumably >> time and datetime constants as well). >> >> For character parameters you can use only unquoted strings. You can't >> use constants in hexadecimal notation. >> >> >> >> On Wed, 13 Jan 2010 13:29 -0600, "Joe Matise" <snoopy369(a)GMAIL.COM> >> wrote: >> > First off, I believe SYSFUNC arguments are intended to be unquoted (no ' >> > " >> > ). 'month' should be month (no quotes). >> > >> > Secondly, "&EndDate"d won't work in the SYSFUNC, as far as I can tell. >> > You'll need to either pass it as a date value, or inside the sysfunc >> > input >> > it into a date value. >> > >> > Finally, you are recursively referenceing EndDate in the %let statement >> - >> > probably not good idea. It doesn't do any harm, but it makes it >> > difficult >> > to see the errors. >> > >> > This works, for example: >> > >> > %macro test( StartDate, EndDate); >> > %let EndDate=%sysfunc(intnx('month',&EndDate,1)); >> > %let StartDate=01&StartDate.; >> > %let where="&StartDate."d<=model<="&EndDate."d; >> > %mend(test); >> > >> > %test( jan09, 17198); >> > >> > -Joe >> > >> > >> > >> > On Wed, Jan 13, 2010 at 12:53 PM, Masoud Pajoh <mpajoh(a)odot.org> wrote: >> > >> > > All: >> > > The following is a fragment of a much larger macro. >> > > >> > > %macro test( StartDate, EndDate); >> > > %let EndDate=%sysfunc(intnx('month',"&EndDate."d,1)); >> > > %let StartDate=01&StartDate.; >> > > %let where="&StartDate."d<=model<="&EndDate."d; >> > > %mend(test); >> > > >> > > %test( jan09, dec09); >> > > >> > > WHERE should resolve to "01jan09"d<=model<="01jan10"d >> > > But, I get: >> > > >> > > WARNING: An argument to the function INTNX referenced by the % SYSFUNC >> or >> > > %QSYSFUNC macro function is out of range. >> > > >> > > What is wrong? >> > > >> > > Thanks, >> > > >> > > Masoud >> > > >> >> >> -- >> Brevis esse laboro, obscurus fio. >> >> Jack Hamilton >> Sacramento, California >> jfh(a)alumni.stanford.org >>