From: Kitabuck on
I recently had my LabVIEW 7.0 upgraded to 8.0.  The technician
uninstalled all run-time engines and software relation to National
Instruments.  he then installed 8.0 and the necessary
drivers.  However when I try to run any of my previous programs, I
get the error "This application has failed to start because nidaq32.dll
was not found."  Our lab had created several data acquisition
programs in 7.0 and now I can't get any of them to work even with the
7.0 run-time engine reinstalled.  Any help with the situation
would be most appreciated.

Thanks,
-Justin
From: Tom W [DE] on
Dennis Knutson wrote:
I think the latest version is 7.4.1.




Indeed it is- download Traditional (Legacy) NI-DAQ 7.4.1 <a href="http://digital.ni.com/softlib.nsf/websearch/3DBF3D343476A28F8625709E006A4937?opendocument&amp;node=132060_US" target="_blank">here</a>. Message Edited by Tom W [DE] on 02-14-2006 02:09 PM
From: Kitabuck on
Thank you very much both of you.&nbsp; That was indeed the solution to the problem.&nbsp;

Thanks,
-Justin