From: Ivan Reyes Ivan on
Hi, I have this error in event viewer...


Event Type: Error
Event Source: NTDS ISAM
Event Category: Database Page Cache
Event ID: 404
Date: 5/3/2007
Time: 12:01:43 PM
User: N/A


Computer: DC1
Description:
NTDS (288) Synchronous read page checksum error -1018 ((1:6844 1:6844)
(0-12987934) (0-13108775)) occurred. Please restore the databases from a
previous backup.


For more information, see Help and Support Center at
http://go.microsoft.com/fwlink/events.asp.


I have two domain controller in the different site, any suggestions?

From: Joe Richards [MVP] on
Wipe the machine, cut the objects from AD that are reflect that DC
(there is a KB for this, look up failed promotion) do low level disk
tests to determine if your hardware is failing, once you know everything
is good, rebuild the OS and dcpromo the machine back up to being a DC.

--
Joe Richards Microsoft MVP Windows Server Directory Services
Author of O'Reilly Active Directory Third Edition
www.joeware.net


---O'Reilly Active Directory Third Edition now available---

http://www.joeware.net/win/ad3e.htm


Ivan Reyes wrote:
> Hi, I have this error in event viewer...
>
>
> Event Type: Error
> Event Source: NTDS ISAM
> Event Category: Database Page Cache
> Event ID: 404
> Date: 5/3/2007
> Time: 12:01:43 PM
> User: N/A
>
>
> Computer: DC1
> Description:
> NTDS (288) Synchronous read page checksum error -1018 ((1:6844 1:6844)
> (0-12987934) (0-13108775)) occurred. Please restore the databases from a
> previous backup.
>
>
> For more information, see Help and Support Center at
> http://go.microsoft.com/fwlink/events.asp.
>
>
> I have two domain controller in the different site, any suggestions?
>
From: Ivan Reyes on
Thank you Joe, I demote the domain controller and rebuilding the array and
reinstall OS and promote domain controller.


"Ivan Reyes" wrote:

> Hi, I have this error in event viewer...
>
>
> Event Type: Error
> Event Source: NTDS ISAM
> Event Category: Database Page Cache
> Event ID: 404
> Date: 5/3/2007
> Time: 12:01:43 PM
> User: N/A
>
>
> Computer: DC1
> Description:
> NTDS (288) Synchronous read page checksum error -1018 ((1:6844 1:6844)
> (0-12987934) (0-13108775)) occurred. Please restore the databases from a
> previous backup.
>
>
> For more information, see Help and Support Center at
> http://go.microsoft.com/fwlink/events.asp.
>
>
> I have two domain controller in the different site, any suggestions?
>