From: Erik on
After installing Navision 4.0 SP3 on a Windows Server 2003 SP2 x64
I'm able to run the application from the console, but when I connect
over a RDP session or ICA using the same admin account,
I'm receive the following error:


Event Type: Error
Event Source: Application Error
Event Category: (100)
Event ID: 1000
Date: 10-8-2007
Time: 11:56:36
User: N/A
Computer: CITRIX01
Description:
Faulting application finsql.exe, version 4.0.3.23305, faulting module
finsql.exe, version 4.0.3.23305, fault address 0x001aba36.

For more information, see Help and Support Center at
http://go.microsoft.com/fwlink/events.asp.
Data:
0000: 41 70 70 6c 69 63 61 74 Applicat
0008: 69 6f 6e 20 46 61 69 6c ion Fail
0010: 75 72 65 20 20 66 69 6e ure fin
0018: 73 71 6c 2e 65 78 65 20 sql.exe
0020: 34 2e 30 2e 33 2e 32 33 4.0.3.23
0028: 33 30 35 20 69 6e 20 66 305 in f
0030: 69 6e 73 71 6c 2e 65 78 insql.ex
0038: 65 20 34 2e 30 2e 33 2e e 4.0.3.
0040: 32 33 33 30 35 20 61 74 23305 at
0048: 20 6f 66 66 73 65 74 20 offset
0050: 30 30 31 61 62 61 33 36 001aba36


The server is running Windows Server 2003 SP2 x64 Eng.
If installed Navision 4.0 SP3 with the admin account using the
change user /install option...
Navision 4.0 SP3 is installed on the following location:
C:\Program Files (x86)\Microsoft Business Solutions-Navision\Client

Anybody a suggestion what this can be for a problem?

Regards,
Erik


From: Erik on
Here is a Solution for the problem:

Change the following key(s)
On a 32 bit OS:
[HKEY_LOCAL_MACHINE\SOFTWARE\Citrix\CtxHook\AppInit_Dlls\Multiple Monitor
Hook]
"Flag"=dword:00000000

On a 64 bit OS:
HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\Citrix\CtxHook\AppInit_Dlls\Multiple
Monitor Hook
"Flag"=dword:00000000

HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\Citrix\CtxHook64\AppInit_Dlls\Multiple Monitor Hook
"Flag"=dword:00000000


Thanks Paul for the Solution ;-)

Regards,
Erik




"Erik" wrote:

> After installing Navision 4.0 SP3 on a Windows Server 2003 SP2 x64
> I'm able to run the application from the console, but when I connect
> over a RDP session or ICA using the same admin account,
> I'm receive the following error:
>
>
> Event Type: Error
> Event Source: Application Error
> Event Category: (100)
> Event ID: 1000
> Date: 10-8-2007
> Time: 11:56:36
> User: N/A
> Computer: CITRIX01
> Description:
> Faulting application finsql.exe, version 4.0.3.23305, faulting module
> finsql.exe, version 4.0.3.23305, fault address 0x001aba36.
>
> For more information, see Help and Support Center at
> http://go.microsoft.com/fwlink/events.asp.
> Data:
> 0000: 41 70 70 6c 69 63 61 74 Applicat
> 0008: 69 6f 6e 20 46 61 69 6c ion Fail
> 0010: 75 72 65 20 20 66 69 6e ure fin
> 0018: 73 71 6c 2e 65 78 65 20 sql.exe
> 0020: 34 2e 30 2e 33 2e 32 33 4.0.3.23
> 0028: 33 30 35 20 69 6e 20 66 305 in f
> 0030: 69 6e 73 71 6c 2e 65 78 insql.ex
> 0038: 65 20 34 2e 30 2e 33 2e e 4.0.3.
> 0040: 32 33 33 30 35 20 61 74 23305 at
> 0048: 20 6f 66 66 73 65 74 20 offset
> 0050: 30 30 31 61 62 61 33 36 001aba36
>
>
> The server is running Windows Server 2003 SP2 x64 Eng.
> If installed Navision 4.0 SP3 with the admin account using the
> change user /install option...
> Navision 4.0 SP3 is installed on the following location:
> C:\Program Files (x86)\Microsoft Business Solutions-Navision\Client
>
> Anybody a suggestion what this can be for a problem?
>
> Regards,
> Erik
>
>