From: Robert Baer on 10 Mar 2010 01:43 John Walliker wrote: > On 9 Mar, 09:12, Robert Baer <robertb...(a)localnet.com> wrote: >> Be advised that every manufacturer has their own design; there are at >> least 3 different circuits being used. >> The TI design is completely different than the ST design. > > Thanks. That is very useful to know. I will bench test with all > makes that are likely to get used in production. Do you know whether > TI are shipping two different designs or just specifying them in > different ways? > > John I do not KNOW if the designs are different, but i believe it is safe to say it is solely specsmanship. National has different TC specs depending on temperature range; looking at their curves (when you can find them) indicates the overall curve from lowest temp to highest temp looks like a parabola with a max at some temperature. Take that curve and slice off a large part of the upper end and some of the lower end,then run a line thru the net average on this new curve and wa-la; the TC has improved maybe an order of magnitude.