From: dunleav1 on
This is a bug that is corrected in FP12. I had to bind the db and the
schema. Whoever applied the patchkit didn't bind the db correctly.

Here's the IBM info:
JR22451: SCHEDULED TASK HANGS AND NEVER FINISHES IN DB2 UDB V8.1 FP10
TASK CENTER
Fixes are available
DB2 Universal Database Version 8.1 FixPak 11 (also known as Version 8.2
FixPak 4
DB2 Universal Database Version 8.1 FixPak 12(also known as Version 8.2
FixPak 5)
APAR status
Closed as program error.
Error description
A scheduled task in the Task Center never finishes after
upgrading to DB2 UDB Version 8.1 FixPak 10 (also known as DB2
UDB Version 8.2 FixPak 3). The Journal shows that the "Success"
of the task is unknown; however, the job itself is completed.
A DB2 Administration Server (DAS) trace shows that, because of a
JNI error, the main DAS thread was unable to reconnect to the
tools catalog database after executing the job successfully.
The following error message is logged in the db2diag.log file:
2005-08-29-08.30.11.532000-300 I3142H386 LEVEL: Error
PID : 512 TID : 4040
FUNCTION: DB2 Tools, DB2 administration server,
MDUtility::connectMD, probe:10
DATA #1 : Sint32, 4 bytes
-300
DATA #2 : Sint32, 4 bytes
0
DATA #3 : Sint32, 4 bytes
0
DATA #4 : String, 7 bytes
TOOLSDB
DATA #5 : String, 8 bytes
SYSTOOLS
DATA #6 : String, 4 bytes
NULL

From: pshindle on

dunleav1 wrote:
> I have the following message in my db2diag.log file repeating every
> minute.
> Does anyone know what the error is ?
>
> 2006-07-10-10.27.08.921000-240 I95651H390 LEVEL: Error
> PID : 3228 TID : 3240
> FUNCTION: DB2 Tools, DB2 administration server, MDUtility::connectMD,
> probe:10
> DATA #1 : Sint32, 4 bytes
> 1
> DATA #2 : Sint32, 4 bytes
> -443
> DATA #3 : Sint32, 4 bytes
> 38553
> DATA #4 : String, 7 bytes
> TOOLSDB
> DATA #5 : String, 8 bytes
> SYSTOOLS
> DATA #6 : String, 4 bytes
> NULL