From: James Hurrell "j_a_hurrell at hotmail on
On 12/04/2010 11:37, James Hurrell wrote:
> On 12/04/2010 11:16, Ayaz Hoda wrote:
>> Event Type: Warning
>> Event Source: SceCli
>> Event Category: None
>> Event ID: 1202
>> Date: 03/06/2009
>> Time: 11:51:40
>> User: N/A
>> Computer:<Server>
>> Description:
>> Security policies were propagated with warning. 0x4b8 : An extended error
>> has occurred.
>>
>
> Lots here:
>
> http://www.eventid.net/display.asp?eventid=1202&eventno=348&source=SceCli&phase=1
>
And more specifically for your hex error:

Error code 0x4b8 (decimal 1208) - "An extended error occurred". See
M260715 - A conflict in Group Policy can cause these events to occur.
These error messages can occur if the "Rename Administrator Account"
security policy is enabled and then set to an account name that is
already in use. Also, as per M285903, to resolve this behavior, remove
all references to the Power Users group in the Local Security settings.