From: Jim McCullars on
Greetings:

Had a hard drive on a Sun Fire 280R go bad and got a replacement from
Sun. Although the system "seems" to be running fine, there are a lot of
messages like this on the console:

Sep 25 14:50:47 hotel picld[75]: Bad file number
Sep 25 14:51:06 hotel picld[75]: Device DISK0 inserted
Sep 25 14:51:06 hotel picld[75]: ERROR running psvc_hotplug_notifier_policy_0 on DISK0 (592312)

It's logging these about every 20 seconds. What kind of problem does this
indicate? We did not turn the machine off before inserting the replacement
drive. Will cycling the power stop these errors? Thanks...

Jim McCullars
University of Alabama in Huntsville
 | 