From: George Herold on
On May 5, 6:09 pm, Nemo <z...(a)nospam.nospam.nospam.nospam.co.uk>
wrote:
> The example I've seen (in a Texas app note) had a few ohms in series
> with the op amp output.
>
> Surely the effective capacitance from inner conductor to shield, which
> you call Cis, is essentially nil because of the driven shield masking
> the C - i.e. the inner conductor does not see a potential difference
> between itself and the outer conductor.
>
> I'm about to try this myself for a pair of cables about 30cm long. I
> chose an AD8626 because -
>
> - the input current is very small
> - bandwidth seemed decent, a few MHz
> - it can drive a few hundred pF
> - it's unity gain stable
> - it has low Cin
> - it can use +/-15V supplies and drive as near the rails as my signals
> are likely to go
>
> I'm connecting the inverting input directly to the output (a voltage
> follower) putting a 1 ohm resistor in series with the output, which will
> drive the shield.
>
> If you need more info let me know and we can email directly.
> --
> Nemo

Hi Nemo, There are three layers. On the outside is ground, next is
the shield, the center of the coax is the signal line from the
resistor. Driving the middle shield, reduces the capacitance between
the inner signal line and outer ground. However it adds the
capacitance from the shield to the inner signal line. I'll look up
the AD8626. And try adding a bit of R in the output line. Do you
have a TI app note number? What sort of source impedance are you
looking at? 100k looks OK, but 10k ohms shows gain peaking.

George H.
From: George Herold on
On May 5, 7:45 pm, John Larkin
<jjlar...(a)highNOTlandTHIStechnologyPART.com> wrote:
> On Wed, 5 May 2010 09:26:32 -0700 (PDT), George Herold
>
>
>
>
>
> <ggher...(a)gmail.com> wrote:
> >I’m looking at the thermal noise from a resistor down the bottom of a
> >probe.  Cable and probe are maybe 1/2 a meter long.  I added a shield
> >line to try and reduce the capacitance between the ‘active’ end of the
> >resistor and ground.  (The other end of the resistor is tied to ground
> >at the bottom of the probe.)
>
> >The driven shield seemed to work great at the higher impedance levels
> >1Meg and 100k ohms. (Though a more careful examination showed there
> >were some issues.)  When I tried 10k ohms there was some serious gain
> >peaking at the higher frequencies...above 100kHz.  I mucked about a
> >bit and made sure this wasn’t the common problem of an opamp driving a
> >capacitive load.
>
> >Late yesterday it struck me that there is capacitive coupling from the
> >shield back to the input.  I had been mistakenly thinking of the
> >shield as only a capacitance to ground.  The capacitance of the inner
> >conductor to the ground (Cig) is 60pF, from the inner conductor to the
> >shield (Cis) is 85pF and from the shield to ground (Csg) is 160pF.
>
> >I was first using an opamp follower to drive the shield, but later
> >added a bit of gain...and then threw it away.
>
> >      +-----Cis--+
> >      |          |
> >      |  |\      |
> >+-----+--+ \     |
> >|        |  >----+---+----+
> >|      +-- / OPA |   |    |
> >Rmeas. | |/  134 |   R1   Csg
> >Rmeas. |         |   R1   |
> >|      +---------+   |    |
> >|                   GND   GND
> >GND
>
> >R1 was 50 ohms (to get rid of Csg ringing)
> >And then this,
>
> >      +-----Cis--+
> >      |          |
> >      |  |\      |
> >+-----+--+ \     |
> >|        |  >----+-R4R4--+----+
> >|      +-- / OPA |       |    |
> >Rmeas. | |/  134 |       R5   Csg
> >Rmeas. |         |       R5   |
> >|      +--R3R3---+       |    |
> >|      |                 GND  GND
> >GND    R2
> >       R2
> >       |
> >       GND
>
> >Where R3 and R4 were 1kohm and R2 and R5 were 100 ohms.
>
> >This seems like it must be a known problem and I wondered if there are
> >any simple solutions.  I thought that a bit of inductance (L =
> >Cis*Rmeas^2) in the right place might help, but I only managed to make
> >a nice oscillator.
>
> >Thanks for any help or advice,
> >George H.
>
> You're trying to measure Johnson noise, right?

Yup, The gain peaking is a real pain.

>
> One problem with any such guarding/bootstrapping scheme is that there
> is a room-temp amplifier that picks up the signal and drives the
> guard, and it has noise of its own. In some cases that makes adding
> the guard a losing battle.

10 k ohms has 40nV/rtHz at room Temp...IIRC.
The opa134 has 8nV of voltage noise.

>
> The OPA134 may be a bit slow, especially driving Csg.

8 MHz GBP. I only need it to work up to 1 MHz or so. Do you have a
better opamp in mind?

>
> What sort of coax are you using? Can you reduce its capacitance?

There is a cable which has ~12" of RG174 (? not sure that's the right
number, small coax) and in the probe there is ~8" of SS coax from
Lakeside cryo. I'm pretty much stuck with the cable I have.

If you go here,
http://www.teachspin.com/newsletters.shtml
And click on the first item (Noise Fundamentals) there are pictures
and such.


George H.

>
> John- Hide quoted text -
>
> - Show quoted text -


From: John Larkin on
On Wed, 5 May 2010 19:57:02 -0700 (PDT), George Herold
<ggherold(a)gmail.com> wrote:

>On May 5, 7:45�pm, John Larkin
><jjlar...(a)highNOTlandTHIStechnologyPART.com> wrote:
>> On Wed, 5 May 2010 09:26:32 -0700 (PDT), George Herold
>>
>>
>>
>>
>>
>> <ggher...(a)gmail.com> wrote:
>> >I�m looking at the thermal noise from a resistor down the bottom of a
>> >probe. �Cable and probe are maybe 1/2 a meter long. �I added a shield
>> >line to try and reduce the capacitance between the �active� end of the
>> >resistor and ground. �(The other end of the resistor is tied to ground
>> >at the bottom of the probe.)
>>
>> >The driven shield seemed to work great at the higher impedance levels
>> >1Meg and 100k ohms. (Though a more careful examination showed there
>> >were some issues.) �When I tried 10k ohms there was some serious gain
>> >peaking at the higher frequencies...above 100kHz. �I mucked about a
>> >bit and made sure this wasn�t the common problem of an opamp driving a
>> >capacitive load.
>>
>> >Late yesterday it struck me that there is capacitive coupling from the
>> >shield back to the input. �I had been mistakenly thinking of the
>> >shield as only a capacitance to ground. �The capacitance of the inner
>> >conductor to the ground (Cig) is 60pF, from the inner conductor to the
>> >shield (Cis) is 85pF and from the shield to ground (Csg) is 160pF.
>>
>> >I was first using an opamp follower to drive the shield, but later
>> >added a bit of gain...and then threw it away.
>>
>> > � � �+-----Cis--+
>> > � � �| � � � � �|
>> > � � �| �|\ � � �|
>> >+-----+--+ \ � � |
>> >| � � � �| �>----+---+----+
>> >| � � �+-- / OPA | � | � �|
>> >Rmeas. | |/ �134 | � R1 � Csg
>> >Rmeas. | � � � � | � R1 � |
>> >| � � �+---------+ � | � �|
>> >| � � � � � � � � � GND � GND
>> >GND
>>
>> >R1 was 50 ohms (to get rid of Csg ringing)
>> >And then this,
>>
>> > � � �+-----Cis--+
>> > � � �| � � � � �|
>> > � � �| �|\ � � �|
>> >+-----+--+ \ � � |
>> >| � � � �| �>----+-R4R4--+----+
>> >| � � �+-- / OPA | � � � | � �|
>> >Rmeas. | |/ �134 | � � � R5 � Csg
>> >Rmeas. | � � � � | � � � R5 � |
>> >| � � �+--R3R3---+ � � � | � �|
>> >| � � �| � � � � � � � � GND �GND
>> >GND � �R2
>> > � � � R2
>> > � � � |
>> > � � � GND
>>
>> >Where R3 and R4 were 1kohm and R2 and R5 were 100 ohms.
>>
>> >This seems like it must be a known problem and I wondered if there are
>> >any simple solutions. �I thought that a bit of inductance (L =
>> >Cis*Rmeas^2) in the right place might help, but I only managed to make
>> >a nice oscillator.
>>
>> >Thanks for any help or advice,
>> >George H.
>>
>> You're trying to measure Johnson noise, right?
>
>Yup, The gain peaking is a real pain.
>
>>
>> One problem with any such guarding/bootstrapping scheme is that there
>> is a room-temp amplifier that picks up the signal and drives the
>> guard, and it has noise of its own. In some cases that makes adding
>> the guard a losing battle.
>
>10 k ohms has 40nV/rtHz at room Temp...IIRC.

Closer to 13.

>The opa134 has 8nV of voltage noise.

10K makes 8 nV at around 100 Kelvin.

>
>>
>> The OPA134 may be a bit slow, especially driving Csg.
>
>8 MHz GBP. I only need it to work up to 1 MHz or so. Do you have a
>better opamp in mind?

How about a BF862 jfet? 0.8 nv/rthz and very low current noise. No
opamp can do that. Cheap, too.

>
>>
>> What sort of coax are you using? Can you reduce its capacitance?
>
>There is a cable which has ~12" of RG174 (? not sure that's the right
>number, small coax) and in the probe there is ~8" of SS coax from
>Lakeside cryo. I'm pretty much stuck with the cable I have.

You can make low-C coax, like they use in scope probes, with a tiny
wire inside a biggish shield, with some low density spacer like spiral
monofilament or something.

If you want to demonstrate Johnson noise vs temperature, it would be a
lot easier to go hot!

John

From: Bill Sloman on
On May 5, 6:26 pm, George Herold <ggher...(a)gmail.com> wrote:
> I’m looking at the thermal noise from a resistor down the bottom of a
> probe.  Cable and probe are maybe 1/2 a meter long.  I added a shield
> line to try and reduce the capacitance between the ‘active’ end of the
> resistor and ground.  (The other end of the resistor is tied to ground
> at the bottom of the probe.)
>
> The driven shield seemed to work great at the higher impedance levels
> 1Meg and 100k ohms. (Though a more careful examination showed there
> were some issues.)  When I tried 10k ohms there was some serious gain
> peaking at the higher frequencies...above 100kHz.  I mucked about a
> bit and made sure this wasn’t the common problem of an opamp driving a
> capacitive load.
>
> Late yesterday it struck me that there is capacitive coupling from the
> shield back to the input.  I had been mistakenly thinking of the
> shield as only a capacitance to ground.  The capacitance of the inner
> conductor to the ground (Cig) is 60pF, from the inner conductor to the
> shield (Cis) is 85pF and from the shield to ground (Csg) is 160pF.
>
> I was first using an opamp follower to drive the shield, but later
> added a bit of gain...and then threw it away.
>
>       +-----Cis--+
>       |          |
>       |  |\      |
> +-----+--+ \     |
> |        |  >----+---+----+
> |      +-- / OPA |   |    |
> Rmeas. | |/  134 |   R1   Csg
> Rmeas. |         |   R1   |
> |      +---------+   |    |
> |                   GND   GND
> GND
>
> R1 was 50 ohms (to get rid of Csg ringing)
> And then this,
>
>       +-----Cis--+
>       |          |
>       |  |\      |
> +-----+--+ \     |
> |        |  >----+-R4R4--+----+
> |      +-- / OPA |       |    |
> Rmeas. | |/  134 |       R5   Csg
> Rmeas. |         |       R5   |
> |      +--R3R3---+       |    |
> |      |                 GND  GND
> GND    R2
>        R2
>        |
>        GND
>
> Where R3 and R4 were 1kohm and R2 and R5 were 100 ohms.
>
> This seems like it must be a known problem and I wondered if there are
> any simple solutions.  I thought that a bit of inductance (L =
> Cis*Rmeas^2) in the right place might help, but I only managed to make
> a nice oscillator.
>
> Thanks for any help or advice,

I don't think that your circuit diagram shows all the necessary
impedances where they ought to be. The OPA134 has finite output
impedance, probably of the order of 100R, and your second circuit
diagram should look more like


+-----Cis----------------------+
| |
| |\ |
+----+-----+--+ \ |
| | | >-----100R-+--R4R4--+----+
| | +-- / OPA | | |
Cig Rmeas. | |/ 134 | R5 Csg
| Rmeas. | | R5 |
| | +--R3R3---------+ | |
| | | GND GND
GND GND R2
R2
|
GND

--
Bill Sloman, Nijmegen
From: George Herold on
On May 5, 11:25 pm, John Larkin
<jjlar...(a)highNOTlandTHIStechnologyPART.com> wrote:
> On Wed, 5 May 2010 19:57:02 -0700 (PDT), George Herold
>
>
>
>
>
> <ggher...(a)gmail.com> wrote:
> >On May 5, 7:45 pm, John Larkin
> ><jjlar...(a)highNOTlandTHIStechnologyPART.com> wrote:
> >> On Wed, 5 May 2010 09:26:32 -0700 (PDT), George Herold
>
> >> <ggher...(a)gmail.com> wrote:
> >> >I’m looking at the thermal noise from a resistor down the bottom of a
> >> >probe.  Cable and probe are maybe 1/2 a meter long.  I added a shield
> >> >line to try and reduce the capacitance between the ‘active’ end of the
> >> >resistor and ground.  (The other end of the resistor is tied to ground
> >> >at the bottom of the probe.)
>
> >> >The driven shield seemed to work great at the higher impedance levels
> >> >1Meg and 100k ohms. (Though a more careful examination showed there
> >> >were some issues.)  When I tried 10k ohms there was some serious gain
> >> >peaking at the higher frequencies...above 100kHz.  I mucked about a
> >> >bit and made sure this wasn’t the common problem of an opamp driving a
> >> >capacitive load.
>
> >> >Late yesterday it struck me that there is capacitive coupling from the
> >> >shield back to the input.  I had been mistakenly thinking of the
> >> >shield as only a capacitance to ground.  The capacitance of the inner
> >> >conductor to the ground (Cig) is 60pF, from the inner conductor to the
> >> >shield (Cis) is 85pF and from the shield to ground (Csg) is 160pF.
>
> >> >I was first using an opamp follower to drive the shield, but later
> >> >added a bit of gain...and then threw it away.
>
> >> >      +-----Cis--+
> >> >      |          |
> >> >      |  |\      |
> >> >+-----+--+ \     |
> >> >|        |  >----+---+----+
> >> >|      +-- / OPA |   |    |
> >> >Rmeas. | |/  134 |   R1   Csg
> >> >Rmeas. |         |   R1   |
> >> >|      +---------+   |    |
> >> >|                   GND   GND
> >> >GND
>
> >> >R1 was 50 ohms (to get rid of Csg ringing)
> >> >And then this,
>
> >> >      +-----Cis--+
> >> >      |          |
> >> >      |  |\      |
> >> >+-----+--+ \     |
> >> >|        |  >----+-R4R4--+----+
> >> >|      +-- / OPA |       |    |
> >> >Rmeas. | |/  134 |       R5   Csg
> >> >Rmeas. |         |       R5   |
> >> >|      +--R3R3---+       |    |
> >> >|      |                 GND  GND
> >> >GND    R2
> >> >       R2
> >> >       |
> >> >       GND
>
> >> >Where R3 and R4 were 1kohm and R2 and R5 were 100 ohms.
>
> >> >This seems like it must be a known problem and I wondered if there are
> >> >any simple solutions.  I thought that a bit of inductance (L =
> >> >Cis*Rmeas^2) in the right place might help, but I only managed to make
> >> >a nice oscillator.
>
> >> >Thanks for any help or advice,
> >> >George H.
>
> >> You're trying to measure Johnson noise, right?
>
> >Yup, The gain peaking is a real pain.
>
> >> One problem with any such guarding/bootstrapping scheme is that there
> >> is a room-temp amplifier that picks up the signal and drives the
> >> guard, and it has noise of its own. In some cases that makes adding
> >> the guard a losing battle.
>
> >10 k ohms has 40nV/rtHz at room Temp...IIRC.
>
> Closer to 13.

Opps, my mistake!
>
> >The opa134 has 8nV of voltage noise.
>
> 10K makes 8 nV at around 100 Kelvin.
>
>
>
> >> The OPA134 may be a bit slow, especially driving Csg.
>
> >8 MHz GBP.  I only need it to work up to 1 MHz or so.  Do you have a
> >better opamp in mind?
>
> How about a BF862 jfet? 0.8 nv/rthz and very low current noise. No
> opamp can do that. Cheap, too.

Hmmm, Roll my own? That's just going to be way too much time for very
little 'gain'. I've basically got to put this to bed for the time
being and get on with other things.

>
>
>
> >> What sort of coax are you using? Can you reduce its capacitance?
>
> >There is a cable which has ~12" of  RG174 (? not sure that's the right
> >number, small coax) and in the probe there is ~8" of SS coax from
> >Lakeside cryo.  I'm pretty much stuck with the cable I have.
>
> You can make low-C coax, like they use in scope probes, with a tiny
> wire inside a biggish shield, with some low density spacer like spiral
> monofilament or something.


>
> If you want to demonstrate Johnson noise vs temperature, it would be a
> lot easier to go hot!

Yup, the news letter doesn't show the data for Johnson noise , but we
change the temperature from 77 K to 373K.


>
> John- Hide quoted text -
>
> - Show quoted text -

If I get the gain peaking under control, then it will be fun to see
how the driven shield changes as the Johnson noise decreases below the
amp noise.... I wonder if I'll get what look likes a peak in the noise
spectrum that is from the driven shield amplifier leaking it's noise
in through the shield capacitance. Fortunately the whole driven
shield idea is not a big part of measuring noise.

George H.