From: Miguel Sanchez on
I have bougth a APC smartups, now i'm trying to set up the powerchute
business edition software. My question is:
How do I tell the UPS to wait 5 minutes after the utility power has gone to
start a shutdown and from there wait 10 minutes before shutting everything
off.
As far as I can see there are 3 items that I need to change, but i have no
idea about their correlation.

Time Required For Shutdown Sequence

Low Battery Signal

OS Shutdown Delay

TIA

Miguel


From: Cliff Galiher on
You should really post product support issues in a group appropriate for
that product. This does not seem like a Windows SBS questions.

Sorry,

-Cliff


"Miguel Sanchez" <santaki2(a)hotmail.com> wrote in message
news:O#LHgvJOKHA.4700(a)TK2MSFTNGP05.phx.gbl...
> I have bougth a APC smartups, now i'm trying to set up the powerchute
> business edition software. My question is:
> How do I tell the UPS to wait 5 minutes after the utility power has gone
> to start a shutdown and from there wait 10 minutes before shutting
> everything off.
> As far as I can see there are 3 items that I need to change, but i have no
> idea about their correlation.
>
> Time Required For Shutdown Sequence
>
> Low Battery Signal
>
> OS Shutdown Delay
>
> TIA
>
> Miguel
>
>
From: Miguel Sanchez on
I know, but the people here seems to be more willing to share their
knowledge that in other groups ;)
Miguel
"Cliff Galiher" <cgaliher(a)gmail.com> escribi� en el mensaje
news:%23Xyf74JOKHA.4004(a)TK2MSFTNGP04.phx.gbl...
> You should really post product support issues in a group appropriate for
> that product. This does not seem like a Windows SBS questions.
>
> Sorry,
>
> -Cliff
>
>
> "Miguel Sanchez" <santaki2(a)hotmail.com> wrote in message
> news:O#LHgvJOKHA.4700(a)TK2MSFTNGP05.phx.gbl...
>> I have bougth a APC smartups, now i'm trying to set up the powerchute
>> business edition software. My question is:
>> How do I tell the UPS to wait 5 minutes after the utility power has gone
>> to start a shutdown and from there wait 10 minutes before shutting
>> everything off.
>> As far as I can see there are 3 items that I need to change, but i have
>> no idea about their correlation.
>>
>> Time Required For Shutdown Sequence
>>
>> Low Battery Signal
>>
>> OS Shutdown Delay
>>
>> TIA
>>
>> Miguel
>>
>>


From: Dave Nickason [SBS MVP] on
I'm not overly familiar with the various versions of the PCBE software, so
yours might be a little different than my slightly older version.

I dbl-click the UPS in the list, which brings up a window called Device
Properties. In there is a Shutdown section. On the Shutdown Sequence page,
you could set the delay to 10 minutes. You should also tell it the duration
(how long the shutdown takes), which you can figure out by timing how long
the server takes to shut down.

Then on the Power Failure page, tell it to begin a shutdown after the UPS
has been on battery for 5 minutes.

Three comments: you're absolutely right, this group is awesome. Once
you've configured PCBE, I recommend testing it to make sure you get the
expected result. And, APC support is generally very good, so I would not
hesitate to shoot them an e-mail if you have questions. I've been happy
with their support from server UPSs like you're using all the way down to
those inexpensive ones that sit under the desk.



"Miguel Sanchez" <santaki2(a)hotmail.com> wrote in message
news:uqTtXGKOKHA.1876(a)TK2MSFTNGP06.phx.gbl...
>I know, but the people here seems to be more willing to share their
>knowledge that in other groups ;)
> Miguel
> "Cliff Galiher" <cgaliher(a)gmail.com> escribi� en el mensaje
> news:%23Xyf74JOKHA.4004(a)TK2MSFTNGP04.phx.gbl...
>> You should really post product support issues in a group appropriate for
>> that product. This does not seem like a Windows SBS questions.
>>
>> Sorry,
>>
>> -Cliff
>>
>>
>> "Miguel Sanchez" <santaki2(a)hotmail.com> wrote in message
>> news:O#LHgvJOKHA.4700(a)TK2MSFTNGP05.phx.gbl...
>>> I have bougth a APC smartups, now i'm trying to set up the powerchute
>>> business edition software. My question is:
>>> How do I tell the UPS to wait 5 minutes after the utility power has gone
>>> to start a shutdown and from there wait 10 minutes before shutting
>>> everything off.
>>> As far as I can see there are 3 items that I need to change, but i have
>>> no idea about their correlation.
>>>
>>> Time Required For Shutdown Sequence
>>>
>>> Low Battery Signal
>>>
>>> OS Shutdown Delay
>>>
>>> TIA
>>>
>>> Miguel
>>>
>>>
>
>

From: SuperGumby [SBS MVP] on
and as all SBS systems should have an attached UPS, I consider it fair to
ask here.

In PowerChute BE, on the page where such settings are shown, there is a
question mark on the title bar, however if you hit the 'configure' button
and then the Qmark on that page there is a better description.

'Use the UPS On Battery Thresholds to set the Runtime Remaining Threshold
for your UPS. This is the threshold at which PowerChute Business Edition
initiates an OS shutdown. The range is from 2 to 59 minutes. For example, if
you set the the Runtime Remaining Threshold to 10 minutes, and your UPS
switches to battery operation, an OS shutdown begins when your UPS's battery
has only 10 minutes of runtime remaining.'

There is, TTBOMK, no way to tell PCBE 'shutdown after a 5 min power loss',
hence, I prefer to use other software.

"Miguel Sanchez" <santaki2(a)hotmail.com> wrote in message
news:uqTtXGKOKHA.1876(a)TK2MSFTNGP06.phx.gbl...
>I know, but the people here seems to be more willing to share their
>knowledge that in other groups ;)
> Miguel
> "Cliff Galiher" <cgaliher(a)gmail.com> escribi� en el mensaje
> news:%23Xyf74JOKHA.4004(a)TK2MSFTNGP04.phx.gbl...
>> You should really post product support issues in a group appropriate for
>> that product. This does not seem like a Windows SBS questions.
>>
>> Sorry,
>>
>> -Cliff
>>
>>
>> "Miguel Sanchez" <santaki2(a)hotmail.com> wrote in message
>> news:O#LHgvJOKHA.4700(a)TK2MSFTNGP05.phx.gbl...
>>> I have bougth a APC smartups, now i'm trying to set up the powerchute
>>> business edition software. My question is:
>>> How do I tell the UPS to wait 5 minutes after the utility power has gone
>>> to start a shutdown and from there wait 10 minutes before shutting
>>> everything off.
>>> As far as I can see there are 3 items that I need to change, but i have
>>> no idea about their correlation.
>>>
>>> Time Required For Shutdown Sequence
>>>
>>> Low Battery Signal
>>>
>>> OS Shutdown Delay
>>>
>>> TIA
>>>
>>> Miguel
>>>
>>>
>
>